.SH NAME
|
|
md \- Multiple Device driver aka Linux Software Raid
|
|
.SH SYNOPSIS
|
|
.BI /dev/md n
|
|
.br
|
|
.BI /dev/md/ n
|
|
.SH DESCRIPTION
|
|
The
|
|
.B md
|
|
driver provides virtual devices that are created from one or more
|
|
independent underlying devices. This array of devices often contains
|
|
redundancy, and hence the acronym RAID which stands for a Redundant
|
|
Array of Independent Devices.
|
|
.PP
|
|
.B md
|
|
supports RAID levels
|
|
1 (mirroring),
|
|
4 (striped array with parity device),
|
|
5 (striped array with distributed parity information),
|
|
6 (striped array with distributed dual redundancy information), and
|
|
10 (striped and mirrored).
|
|
If some number of underlying devices fails while using one of these
|
|
levels, the array will continue to function; this number is one for
|
|
RAID levels 4 and 5, two for RAID level 6, and all but one (N-1) for
|
|
RAID level 1, and dependant on configuration for level 10.
|
|
.PP
|
|
.B md
|
|
also supports a number of pseudo RAID (non-redundant) configurations
|
|
including RAID0 (striped array), LINEAR (catenated array),
|
|
MULTIPATH (a set of different interfaces to the same device),
|
|
and FAULTY (a layer over a single device into which errors can be injected).
|
|
|
|
.SS MD SUPER BLOCK
|
|
Each device in an array may have a
|
|
.I superblock
|
|
which records information about the structure and state of the array.
|
|
This allows the array to be reliably re-assembled after a shutdown.
|
|
|
|
From Linux kernel version 2.6.10,
|
|
.B md
|
|
provides support for two different formats of this superblock, and
|
|
other formats can be added. Prior to this release, only one format is
|
|
supported.
|
|
|
|
The common format - known as version 0.90 - has
|
|
a superblock that is 4K long and is written into a 64K aligned block that
|
|
starts at least 64K and less than 128K from the end of the device
|
|
(i.e. to get the address of the superblock round the size of the
|
|
device down to a multiple of 64K and then subtract 64K).
|
|
The available size of each device is the amount of space before the
|
|
super block, so between 64K and 128K is lost when a device in
|
|
incorporated into an MD array.
|
|
This superblock stores multi-byte fields in a processor-dependant
|
|
manner, so arrays cannot easily be moved between computers with
|
|
different processors.
|
|
|
|
The new format - known as version 1 - has a superblock that is
|
|
normally 1K long, but can be longer. It is normally stored between 8K
|
|
and 12K from the end of the device, on a 4K boundary, though
|
|
variations can be stored at the start of the device (version 1.1) or 4K from
|
|
the start of the device (version 1.2).
|
|
This superblock format stores multibyte data in a
|
|
processor-independent format and has supports up to hundreds of
|
|
component devices (version 0.90 only supports 28).
|
|
|
|
The superblock contains, among other things:
|
|
.TP
|
|
LEVEL
|
|
The manner in which the devices are arranged into the array
|
|
(linear, raid0, raid1, raid4, raid5, raid10, multipath).
|
|
.TP
|
|
UUID
|
|
a 128 bit Universally Unique Identifier that identifies the array that
|
|
this device is part of.
|
|
|
|
When a version 0.90 array is being reshaped (e.g. adding extra devices
|
|
to a RAID5), the version number is temporarily set to 0.91. This
|
|
ensures that if the reshape process is stopped in the middle (e.g. by
|
|
a system crash) and the machine boots into an older kernel that does
|
|
not support reshaping, then the array will not be assembled (which
|
|
would cause data corruption) but will be left untouched until a kernel
|
|
that can complete the reshape processes is used.
|
|
|
|
.SS ARRAYS WITHOUT SUPERBLOCKS
|
|
While it is usually best to create arrays with superblocks so that
|
|
they can be assembled reliably, there are some circumstances where an
|
|
array without superblocks in preferred. This include:
|
|
.TP
|
|
LEGACY ARRAYS
|
|
Early versions of the
|
|
.B md
|
|
driver only supported Linear and Raid0 configurations and did not use
|
|
a superblock (which is less critical with these configurations).
|
|
While such arrays should be rebuilt with superblocks if possible,
|
|
.B md
|
|
continues to support them.
|
|
.TP
|
|
FAULTY
|
|
Being a largely transparent layer over a different device, the FAULTY
|
|
personality doesn't gain anything from having a superblock.
|
|
.TP
|
|
MULTIPATH
|
|
It is often possible to detect devices which are different paths to
|
|
the same storage directly rather than having a distinctive superblock
|
|
written to the device and searched for on all paths. In this case,
|
|
a MULTIPATH array with no superblock makes sense.
|
|
.TP
|
|
RAID1
|
|
In some configurations it might be desired to create a raid1
|
|
configuration that does use a superblock, and to maintain the state of
|
|
the array elsewhere. While not encouraged for general us, it does
|
|
have special-purpose uses and is supported.
|
|
|
|
.SS LINEAR
|
|
|
|
A linear array simply catenates the available space on each
|
|
drive together to form one large virtual drive.
|
|
|
|
One advantage of this arrangement over the more common RAID0
|
|
arrangement is that the array may be reconfigured at a later time with
|
|
an extra drive and so the array is made bigger without disturbing the
|
|
data that is on the array. However this cannot be done on a live
|
|
array.
|
|
|
|
If a chunksize is given with a LINEAR array, the usable space on each
|
|
device is rounded down to a multiple of this chunksize.
|
|
|
|
.SS RAID0
|
|
|
|
A RAID0 array (which has zero redundancy) is also known as a
|
|
striped array.
|
|
A RAID0 array is configured at creation with a
|
|
.B "Chunk Size"
|
|
which must be a power of two, and at least 4 kibibytes.
|
|
|
|
The RAID0 driver assigns the first chunk of the array to the first
|
|
device, the second chunk to the second device, and so on until all
|
|
drives have been assigned one chunk. This collection of chunks forms
|
|
a
|
|
.BR stripe .
|
|
Further chunks are gathered into stripes in the same way which are
|
|
assigned to the remaining space in the drives.
|
|
|
|
If devices in the array are not all the same size, then once the
|
|
smallest device has been exhausted, the RAID0 driver starts
|
|
collecting chunks into smaller stripes that only span the drives which
|
|
still have remaining space.
|
|
|
|
|
|
.SS RAID1
|
|
|
|
A RAID1 array is also known as a mirrored set (though mirrors tend to
|
|
provide reflected images, which RAID1 does not) or a plex.
|
|
|
|
Once initialised, each device in a RAID1 array contains exactly the
|
|
same data. Changes are written to all devices in parallel. Data is
|
|
read from any one device. The driver attempts to distribute read
|
|
requests across all devices to maximise performance.
|
|
|
|
All devices in a RAID1 array should be the same size. If they are
|
|
not, then only the amount of space available on the smallest device is
|
|
used. Any extra space on other devices is wasted.
|
|
|
|
.SS RAID4
|
|
|
|
A RAID4 array is like a RAID0 array with an extra device for storing
|
|
parity. This device is the last of the active devices in the
|
|
array. Unlike RAID0, RAID4 also requires that all stripes span all
|
|
drives, so extra space on devices that are larger than the smallest is
|
|
wasted.
|
|
|
|
When any block in a RAID4 array is modified the parity block for that
|
|
stripe (i.e. the block in the parity device at the same device offset
|
|
as the stripe) is also modified so that the parity block always
|
|
contains the "parity" for the whole stripe. i.e. its contents is
|
|
equivalent to the result of performing an exclusive-or operation
|
|
between all the data blocks in the stripe.
|
|
|
|
This allows the array to continue to function if one device fails.
|
|
The data that was on that device can be calculated as needed from the
|
|
parity block and the other data blocks.
|
|
|
|
.SS RAID5
|
|
|
|
RAID5 is very similar to RAID4. The difference is that the parity
|
|
blocks for each stripe, instead of being on a single device, are
|
|
distributed across all devices. This allows more parallelism when
|
|
writing as two different block updates will quite possibly affect
|
|
parity blocks on different devices so there is less contention.
|
|
|
|
This also allows more parallelism when reading as read requests are
|
|
distributed over all the devices in the array instead of all but one.
|
|
|
|
.SS RAID6
|
|
|
|
RAID6 is similar to RAID5, but can handle the loss of any \fItwo\fP
|
|
devices without data loss. Accordingly, it requires N+2 drives to
|
|
store N drives worth of data.
|
|
|
|
The performance for RAID6 is slightly lower but comparable to RAID5 in
|
|
normal mode and single disk failure mode. It is very slow in dual
|
|
disk failure mode, however.
|
|
|
|
.SS RAID10
|
|
|
|
RAID10 provides a combination of RAID1 and RAID0, and sometimes known
|
|
as RAID1+0. Every datablock is duplicated some number of times, and
|
|
the resulting collection of datablocks are distributed over multiple
|
|
drives.
|
|
|
|
When configuring a RAID10 array it is necessary to specify the number
|
|
of replicas of each data block that are required (this will normally
|
|
be 2) and whether the replicas should be 'near', 'offset' or 'far'.
|
|
(Note that the 'offset' layout is only available from 2.6.18).
|
|
|
|
When 'near' replicas are chosen, the multiple copies of a given chunk
|
|
are laid out consecutively across the stripes of the array, so the two
|
|
copies of a datablock will likely be at the same offset on two
|
|
adjacent devices.
|
|
|
|
When 'far' replicas are chosen, the multiple copies of a given chunk
|
|
are laid out quite distant from each other. The first copy of all
|
|
data blocks will be striped across the early part of all drives in
|
|
RAID0 fashion, and then the next copy of all blocks will be striped
|
|
across a later section of all drives, always ensuring that all copies
|
|
of any given block are on different drives.
|
|
|
|
The 'far' arrangement can give sequential read performance equal to
|
|
that of a RAID0 array, but at the cost of degraded write performance.
|
|
|
|
When 'offset' replicas are chosen, the multiple copies of a given
|
|
chunk are laid out on consecutive drives and at consecutive offsets.
|
|
Effectively each stripe is duplicated and the copies are offset by one
|
|
device. This should give similar read characteristics to 'far' if a
|
|
suitably large chunk size is used, but without as much seeking for
|
|
writes.
|
|
|
|
It should be noted that the number of devices in a RAID10 array need
|
|
not be a multiple of the number of replica of each data block, those
|
|
there must be at least as many devices as replicas.
|
|
|
|
If, for example, an array is created with 5 devices and 2 replicas,
|
|
then space equivalent to 2.5 of the devices will be available, and
|
|
every block will be stored on two different devices.
|
|
|
|
Finally, it is possible to have an array with both 'near' and 'far'
|
|
copies. If and array is configured with 2 near copies and 2 far
|
|
copies, then there will be a total of 4 copies of each block, each on
|
|
a different drive. This is an artifact of the implementation and is
|
|
unlikely to be of real value.
|
|
|
|
.SS MUTIPATH
|
|
|
|
MULTIPATH is not really a RAID at all as there is only one real device
|
|
in a MULTIPATH md array. However there are multiple access points
|
|
(paths) to this device, and one of these paths might fail, so there
|
|
are some similarities.
|
|
|
|
A MULTIPATH array is composed of a number of logically different
|
|
devices, often fibre channel interfaces, that all refer the the same
|
|
real device. If one of these interfaces fails (e.g. due to cable
|
|
problems), the multipath driver will attempt to redirect requests to
|
|
another interface.
|
|
|
|
.SS FAULTY
|
|
The FAULTY md module is provided for testing purposes. A faulty array
|
|
has exactly one component device and is normally assembled without a
|
|
superblock, so the md array created provides direct access to all of
|
|
the data in the component device.
|
|
|
|
The FAULTY module may be requested to simulate faults to allow testing
|
|
of other md levels or of filesystems. Faults can be chosen to trigger
|
|
on read requests or write requests, and can be transient (a subsequent
|
|
read/write at the address will probably succeed) or persistent
|
|
(subsequent read/write of the same address will fail). Further, read
|
|
faults can be "fixable" meaning that they persist until a write
|
|
request at the same address.
|
|
|
|
Fault types can be requested with a period. In this case the fault
|
|
will recur repeatedly after the given number of requests of the
|
|
relevant type. For example if persistent read faults have a period of
|
|
100, then every 100th read request would generate a fault, and the
|
|
faulty sector would be recorded so that subsequent reads on that
|
|
sector would also fail.
|
|
|
|
There is a limit to the number of faulty sectors that are remembered.
|
|
Faults generated after this limit is exhausted are treated as
|
|
transient.
|
|
|
|
The list of faulty sectors can be flushed, and the active list of
|
|
failure modes can be cleared.
|
|
|
|
.SS UNCLEAN SHUTDOWN
|
|
|
|
When changes are made to a RAID1, RAID4, RAID5, RAID6, or RAID10 array
|
|
there is a possibility of inconsistency for short periods of time as
|
|
each update requires are least two block to be written to different
|
|
devices, and these writes probably wont happen at exactly the same
|
|
time. Thus if a system with one of these arrays is shutdown in the
|
|
middle of a write operation (e.g. due to power failure), the array may
|
|
not be consistent.
|
|
|
|
To handle this situation, the md driver marks an array as "dirty"
|
|
before writing any data to it, and marks it as "clean" when the array
|
|
is being disabled, e.g. at shutdown. If the md driver finds an array
|
|
to be dirty at startup, it proceeds to correct any possibly
|
|
inconsistency. For RAID1, this involves copying the contents of the
|
|
first drive onto all other drives. For RAID4, RAID5 and RAID6 this
|
|
involves recalculating the parity for each stripe and making sure that
|
|
the parity block has the correct data. For RAID10 it involves copying
|
|
one of the replicas of each block onto all the others. This process,
|
|
known as "resynchronising" or "resync" is performed in the background.
|
|
The array can still be used, though possibly with reduced performance.
|
|
|
|
If a RAID4, RAID5 or RAID6 array is degraded (missing at least one
|
|
drive) when it is restarted after an unclean shutdown, it cannot
|
|
recalculate parity, and so it is possible that data might be
|
|
undetectably corrupted. The 2.4 md driver
|
|
.B does not
|
|
alert the operator to this condition. The 2.6 md driver will fail to
|
|
start an array in this condition without manual intervention, though
|
|
this behaviour can be over-ridden by a kernel parameter.
|
|
|
|
.SS RECOVERY
|
|
|
|
If the md driver detects a write error on a device in a RAID1, RAID4,
|
|
RAID5, RAID6, or RAID10 array, it immediately disables that device
|
|
(marking it as faulty) and continues operation on the remaining
|
|
devices. If there is a spare drive, the driver will start recreating
|
|
on one of the spare drives the data what was on that failed drive,
|
|
either by copying a working drive in a RAID1 configuration, or by
|
|
doing calculations with the parity block on RAID4, RAID5 or RAID6, or
|
|
by finding a copying originals for RAID10.
|
|
|
|
In kernels prior to about 2.6.15, a read error would cause the same
|
|
effect as a write error. In later kernels, a read-error will instead
|
|
cause md to attempt a recovery by overwriting the bad block. i.e. it
|
|
will find the correct data from elsewhere, write it over the block
|
|
that failed, and then try to read it back again. If either the write
|
|
or the re-read fail, md will treat the error the same way that a write
|
|
error is treated and will fail the whole device.
|
|
|
|
While this recovery process is happening, the md driver will monitor
|
|
accesses to the array and will slow down the rate of recovery if other
|
|
activity is happening, so that normal access to the array will not be
|
|
unduly affected. When no other activity is happening, the recovery
|
|
process proceeds at full speed. The actual speed targets for the two
|
|
different situations can be controlled by the
|
|
.B speed_limit_min
|
|
and
|
|
.B speed_limit_max
|
|
control files mentioned below.
|
|
|
|
.SS BITMAP WRITE-INTENT LOGGING
|
|
|
|
From Linux 2.6.13,
|
|
.I md
|
|
supports a bitmap based write-intent log. If configured, the bitmap
|
|
is used to record which blocks of the array may be out of sync.
|
|
Before any write request is honoured, md will make sure that the
|
|
corresponding bit in the log is set. After a period of time with no
|
|
writes to an area of the array, the corresponding bit will be cleared.
|
|
|
|
This bitmap is used for two optimisations.
|
|
|
|
Firstly, after an unclear shutdown, the resync process will consult
|
|
the bitmap and only resync those blocks that correspond to bits in the
|
|
bitmap that are set. This can dramatically increase resync time.
|
|
|
|
Secondly, when a drive fails and is removed from the array, md stops
|
|
clearing bits in the intent log. If that same drive is re-added to
|
|
the array, md will notice and will only recover the sections of the
|
|
drive that are covered by bits in the intent log that are set. This
|
|
can allow a device to be temporarily removed and reinserted without
|
|
causing an enormous recovery cost.
|
|
|
|
The intent log can be stored in a file on a separate device, or it can
|
|
be stored near the superblocks of an array which has superblocks.
|
|
|
|
It is possible to add an intent log or an active array, or remove an
|
|
intent log if one is present.
|
|
|
|
In 2.6.13, intent bitmaps are only supported with RAID1. Other levels
|
|
with redundancy are supported from 2.6.15.
|
|
|
|
.SS WRITE-BEHIND
|
|
|
|
From Linux 2.6.14,
|
|
.I md
|
|
supports WRITE-BEHIND on RAID1 arrays.
|
|
|
|
This allows certain devices in the array to be flagged as
|
|
.IR write-mostly .
|
|
MD will only read from such devices if there is no
|
|
other option.
|
|
|
|
If a write-intent bitmap is also provided, write requests to
|
|
write-mostly devices will be treated as write-behind requests and md
|
|
will not wait for writes to those requests to complete before
|
|
reporting the write as complete to the filesystem.
|
|
|
|
This allows for a RAID1 with WRITE-BEHIND to be used to mirror data
|
|
over a slow link to a remove computer (providing the link isn't too
|
|
slow). The extra latency of the remote link will not slow down normal
|
|
operations, but the remote system will still have a reasonably
|
|
up-to-date copy of all data.
|
|
|
|
.SS RESTRIPING
|
|
|
|
.IR Restriping ,
|
|
also known as
|
|
.IR Reshaping ,
|
|
is the processes of re-arranging the data stored in each stripe into a
|
|
new layout. This might involve changing the number of devices in the
|
|
array (so the stripes are wider) changing the chunk size (so stripes
|
|
are deeper or shallower), or changing the arrangement of data and
|
|
parity, possibly changing the raid level (e.g. 1 to 5 or 5 to 6).
|
|
|
|
As of Linux 2.6.17, md can reshape a raid5 array to have more
|
|
devices. Other possibilities may follow in future kernels.
|
|
|
|
During any stripe process there is a 'critical section' during which
|
|
live data is being over-written on disk. For the operation of
|
|
increasing the number of drives in a raid5, this critical section
|
|
covers the first few stripes (the number being the product of the old
|
|
and new number of devices). After this critical section is passed,
|
|
data is only written to areas of the array which no longer hold live
|
|
data - the live data has already been located away.
|
|
|
|
md is not able to ensure data preservation if there is a crash
|
|
(e.g. power failure) during the critical section. If md is asked to
|
|
start an array which failed during a critical section of restriping,
|
|
it will fail to start the array.
|
|
|
|
To deal with this possibility, a user-space program must
|
|
.IP \(bu 4
|
|
Disable writes to that section of the array (using the
|
|
.B sysfs
|
|
interface),
|
|
.IP \(bu 4
|
|
Take a copy of the data somewhere (i.e. make a backup)
|
|
.IP \(bu 4
|
|
Allow the process to continue and invalidate the backup and restore
|
|
write access once the critical section is passed, and
|
|
.IP \(bu 4
|
|
Provide for restoring the critical data before restarting the array
|
|
after a system crash.
|
|
.PP
|
|
|
|
.B mdadm
|
|
version 2.4 and later will do this for growing a RAID5 array.
|
|
|
|
For operations that do not change the size of the array, like simply
|
|
increasing chunk size, or converting RAID5 to RAID6 with one extra
|
|
device, the entire process is the critical section. In this case the
|
|
restripe will need to progress in stages as a section is suspended,
|
|
backed up,
|
|
restriped, and released. This is not yet implemented.
|
|
|
|
.SS SYSFS INTERFACE
|
|
All block devices appear as a directory in
|
|
.I sysfs
|
|
(usually mounted at
|
|
.BR /sys ).
|
|
For MD devices, this directory will contain a subdirectory called
|
|
.B md
|
|
which contains various files for providing access to information about
|
|
the array.
|
|
|
|
This interface is documented more fully in the file
|
|
.B Documentation/md.txt
|
|
which is distributed with the kernel sources. That file should be
|
|
consulted for full documentation. The following are just a selection
|
|
of attribute files that are available.
|
|
|
|
.TP
|
|
.B md/sync_speed_min
|
|
This value, if set, overrides the system-wide setting in
|
|
.B /proc/sys/dev/raid/speed_limit_min
|
|
for this array only.
|
|
Writing the value
|
|
.B system
|
|
to this file cause the system-wide setting to have effect.
|
|
|
|
.TP
|
|
.B md/sync_speed_max
|
|
This is the partner of
|
|
.B md/sync_speed_min
|
|
and overrides
|
|
.B /proc/sys/dev/raid/spool_limit_max
|
|
described below.
|
|
|
|
.TP
|
|
.B md/sync_action
|
|
This can be used to monitor and control the resync/recovery process of
|
|
MD.
|
|
In particular, writing "check" here will cause the array to read all
|
|
data block and check that they are consistent (e.g. parity is correct,
|
|
or all mirror replicas are the same). Any discrepancies found are
|
|
.B NOT
|
|
corrected.
|
|
|
|
A count of problems found will be stored in
|
|
.BR md/mismatch_count .
|
|
|
|
Alternately, "repair" can be written which will cause the same check
|
|
to be performed, but any errors will be corrected.
|
|
|
|
Finally, "idle" can be written to stop the check/repair process.
|
|
|
|
.TP
|
|
.B md/stripe_cache_size
|
|
This is only available on RAID5 and RAID6. It records the size (in
|
|
pages per device) of the stripe cache which is used for synchronising
|
|
all read and write operations to the array. The default is 128.
|
|
Increasing this number can increase performance in some situations, at
|
|
some cost in system memory.
|
|
|
|
|
|
.SS KERNEL PARAMETERS
|
|
|
|
The md driver recognised several different kernel parameters.
|
|
.TP
|
|
.B raid=noautodetect
|
|
This will disable the normal detection of md arrays that happens at
|
|
boot time. If a drive is partitioned with MS-DOS style partitions,
|
|
then if any of the 4 main partitions has a partition type of 0xFD,
|
|
then that partition will normally be inspected to see if it is part of
|
|
an MD array, and if any full arrays are found, they are started. This
|
|
kernel parameter disables this behaviour.
|
|
|
|
.TP
|
|
.B raid=partitionable
|
|
.TP
|
|
.B raid=part
|
|
These are available in 2.6 and later kernels only. They indicate that
|
|
autodetected MD arrays should be created as partitionable arrays, with
|
|
a different major device number to the original non-partitionable md
|
|
arrays. The device number is listed as
|
|
.I mdp
|
|
in
|
|
.IR /proc/devices .
|
|
|
|
.TP
|
|
.B md_mod.start_ro=1
|
|
This tells md to start all arrays in read-only mode. This is a soft
|
|
read-only that will automatically switch to read-write on the first
|
|
write request. However until that write request, nothing is written
|
|
to any device by md, and in particular, no resync or recovery
|
|
operation is started.
|
|
|
|
.TP
|
|
.B md_mod.start_dirty_degraded=1
|
|
As mentioned above, md will not normally start a RAID4, RAID5, or
|
|
RAID6 that is both dirty and degraded as this situation can imply
|
|
hidden data loss. This can be awkward if the root filesystem is
|
|
affected. Using the module parameter allows such arrays to be started
|
|
at boot time. It should be understood that there is a real (though
|
|
small) risk of data corruption in this situation.
|
|
|
|
.TP
|
|
.BI md= n , dev , dev ,...
|
|
.TP
|
|
.BI md=d n , dev , dev ,...
|
|
This tells the md driver to assemble
|
|
.B /dev/md n
|
|
from the listed devices. It is only necessary to start the device
|
|
holding the root filesystem this way. Other arrays are best started
|
|
once the system is booted.
|
|
|
|
In 2.6 kernels, the
|
|
.B d
|
|
immediately after the
|
|
.B =
|
|
indicates that a partitionable device (e.g.
|
|
.BR /dev/md/d0 )
|
|
should be created rather than the original non-partitionable device.
|
|
|
|
.TP
|
|
.BI md= n , l , c , i , dev...
|
|
This tells the md driver to assemble a legacy RAID0 or LINEAR array
|
|
without a superblock.
|
|
.I n
|
|
gives the md device number,
|
|
.I l
|
|
gives the level, 0 for RAID0 or -1 for LINEAR,
|
|
.I c
|
|
gives the chunk size as a base-2 logarithm offset by twelve, so 0
|
|
means 4K, 1 means 8K.
|
|
.I i
|
|
is ignored (legacy support).
|
|
|
|
.SH FILES
|
|
.TP
|
|
.B /proc/mdstat
|
|
Contains information about the status of currently running array.
|
|
.TP
|
|
.B /proc/sys/dev/raid/speed_limit_min
|
|
A readable and writable file that reflects the current goal rebuild
|
|
speed for times when non-rebuild activity is current on an array.
|
|
The speed is in Kibibytes per second, and is a per-device rate, not a
|
|
per-array rate (which means that an array with more disc will shuffle
|
|
more data for a given speed). The default is 100.
|
|
|
|
.TP
|
|
.B /proc/sys/dev/raid/speed_limit_max
|
|
A readable and writable file that reflects the current goal rebuild
|
|
speed for times when no non-rebuild activity is current on an array.
|
|
The default is 100,000.
|
|
|
|
.SH SEE ALSO
|
|