imsm: fix failed disks are allowed back into the container
Failed disks do not have valid serial numbers which means we will not pick up the 'failed' status bit from the metadata entry. Check for dl->index == -2 to prevent failed disks from being incorporated into the container. Signed-off-by: Dan Williams <dan.j.williams@intel.com>
This commit is contained in:
parent
5615172f1d
commit
caf8d23175
|
@ -1195,8 +1195,11 @@ static void getinfo_super_imsm(struct supertype *st, struct mdinfo *info)
|
|||
info->component_size = reserved;
|
||||
s = disk->status;
|
||||
info->disk.state = s & CONFIGURED_DISK ? (1 << MD_DISK_ACTIVE) : 0;
|
||||
info->disk.state |= s & FAILED_DISK ? (1 << MD_DISK_FAULTY) : 0;
|
||||
info->disk.state |= s & SPARE_DISK ? 0 : (1 << MD_DISK_SYNC);
|
||||
if (s & FAILED_DISK || super->disks->index == -2) {
|
||||
info->disk.state |= 1 << MD_DISK_FAULTY;
|
||||
info->disk.raid_disk = -2;
|
||||
}
|
||||
}
|
||||
|
||||
/* only call uuid_from_super_imsm when this disk is part of a populated container,
|
||||
|
|
Loading…